Authors: | M. Kallinger, J. Bitzer, K.-D. Kammeyer | ||||||
Abstract: | In this paper, we will compare different combinations of a multi-channel non-adaptive noise reduction unit (NRU) and an acoustic echo cancellation unit (AEC) for a standard single-channel voice transmission. The results show that the NRU and the AEC-unit can be interchanged without increasing the computational complexity of the combined system. The length of an AEC’s adaptive filter can be greatly reduced, if a multi-channel AEC-unit in front of a multichannel NRU is used. Furthermore, the control information, like the step-size of the NLMS-algorithm, has to be computed only once. |
||||||
Document type: | Conference Paper | ||||||
Publication: | Istanbul, Turkey, 5. - 9. June 2000 | ||||||
Conference: | International Conference on Acoustics Speech and Signal Processing (ICASSP 2000) | ||||||
Index: | 90 | ||||||
Files: |
|